Acceptance of ET44 in 2000.
V.Andreev, 09-June-2002
The 2000 H1 running period was devided on 7 samples which
have the different offset or tilt of the electron beam in
the interaction point.
The list of this samples is shown bellow :
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
TransActID Rtyp Dtyp 1.Run Words Author Date
2648094 e-p data 262200 70 vladimir 001113
2648095 e-p data 263381 70 vladimir 001113
2648096 e-p data 267501 70 vladimir 001113
2648097 e-p data 271601 70 vladimir 001113
2648098 e-p data 274881 70 vladimir 001113
2648099 e-p data 275801 70 vladimir 001113
2648100 e-p data 277601 70 vladimir 001113
ET44 acceptance was calculated for each sample using the standart
procedure described in the H1 note #493
and then the DB base was update by the new set of LET1 banks.
The y-dependence of ET44 acceptance for different run periods is
shown on picture and the same distributions for the previous years
are also given for the comparision on the next acc-1999,
acc-old pictures.
The systematic error of the acceptance determination for ET44
in 200 is formed by the next parts:
a) uncertainty in the energy scale determination --> 2.5 % ,
b) trigger efficiency --> 1.0 % ,
c) error connected with the uncertainty in the position
of ET44 with respect to the electron beam --> 3.5 % ,
d) error which reflects the averaging of the several
calibration sets --> 1.6 % ,
e) uncertainty connected with the fit procedure --> 0.6 % ,
e) uncertainty connected with the limited y-range --> 0.6 % .
So the overall systematic error in the acceptance determination
of ET44 in 2000 is equal 4.8 % .
More details for the previos years one can also find in the
description of 1999, 1998 , 1997 and 1996 .